  • Máy biến áp bơm hơi dòng YDQW không dùng cho thử nghiệm phóng điện cục bộ

    Khí SF6 có độ bền cách điện cao, được sử dụng làm môi trường cách điện. Khả năng phóng điện cục bộ nhỏ, điện áp định mức, khả năng phóng điện cục bộ ≤ 5PC. Sản phẩm có chất lượng chế tạo cao, ngoại hình đẹp và dễ sử dụng.

    Product Details of YDQW Series Inflatable No Partial Discharge Test Transformer

    b5b8fc71abe60022cf61860187f435cd


    Product parameters:

    Used for manufacturers of electrical appliances, cables, motors, transformers, mutual inductors, insulation materials, and related high-voltage components, as well as high-voltage testing laboratories in power, scientific research, and universities, to conduct partial discharge and power frequency withstand voltage tests on their products.

    aa73a372533993b0e04275fffd83e738


    Technical parameters:

    Người mẫu

    Matching KVA with YDQW

    YDQW-2

    1.5

    YDQW -3

    3

    YDQW -5

    5

    YDQW -10

    10

    YDQW -20

    20

    YDQW -30

    30

    YDQW -50

    50

    1. For transformers of various voltage levels, the no-load current is 4-9% and the impedance voltage is 4-10%.

    2. Control the existing specifications and operating time of the control part.

    Note: Can be matched according to user requirements


    Tính năng:

    1. The design concept, material selection, and process flow are all brand new, so not only is it small in size, light in weight, and beautiful in appearance, but all technical indicators have met the requirements of JB3570-98 standard.

    2. Made using a completely new process, the dielectric insulation material used is completely different from other products, resulting in a product with no partial discharge effect.


    working principle:

    The control panel (box) with overcurrent automatic tripping and zero position interlocking device to prevent sudden pressurization of the power input is regulated by an autotransformer to input voltage into a non partial discharge filter isolation filter transformer, and then output from the non partial discharge filter isolation filter transformer

    To test the primary winding of the transformer, according to the principle of electromagnetic induction, the secondary (high voltage) winding can obtain an equal multiple of voltage amplitude - power frequency high voltage - based on the ratio of its turns to the primary winding.










    Bạn cũng có thể thích

    • Có bất kỳ câu hỏi nào!

      ĐỪNG ngần ngại LIÊN HỆ VỚI CHÚNG TÔI BẤT CỨ LÚC NÀO
      Liên hệ chúng tôi
    • Ghé thăm chúng tôi

      Tòa nhà 6, Khu công nghiệp Cơ khí Quang học Thung lũng Quang học, 84 Đường Gaoxin 5,
      Khu phát triển công nghệ mới Hồ Đông, thành phố Vũ Hán, tỉnh Hồ Bắc, Trung Quốc

    • Gửi email cho chúng tôi

      qiao@hvtest.cc

    • Gọi cho chúng tôi

      +86-15871365102