  • Máy biến áp bơm hơi dòng YDQW không dùng cho thử nghiệm phóng điện cục bộ

    Khí SF6 có độ bền cách điện cao, được sử dụng làm môi trường cách điện. Khả năng phóng điện cục bộ nhỏ, điện áp định mức, khả năng phóng điện cục bộ ≤ 5PC. Sản phẩm có chất lượng chế tạo cao, ngoại hình đẹp và dễ sử dụng.

    Product Details of YDQW Series Inflatable No Partial Discharge Test Transformer

    Product Introduction:

    Used for manufacturers of electrical appliances, cables, motors, transformers, mutual inductors, insulation materials, and related high-voltage components, as well as high-voltage testing laboratories in power, scientific research, and universities, to conduct partial discharge and power frequency withstand voltage tests on their products.


    Technical parameters:

    Thông số

    Value

    Công suất định mức

    50-1200kVA

    Điện áp đầu vào

    380V

    Điện áp đầu ra

    50-1200kV

    Thời gian chạy

    5 phút

    Đo lường độ chính xác

    ≤1.5%

    Partial discharge capacity

    ≤5Pc

    Protection function

    Overcurrent and voltage protection alarm automatically return to zero


    Tính năng:

    1. Filled with SF6 gas, which features high insulation strength, as the insulating medium.

    2. Compact and lightweight design with high-quality craftsmanship, attractive appearance, and easy handling.

    3. Benefiting from the arc-extinguishing properties and specialized structural design involving SF6 gas, the unit exhibits low partial discharge levels, measuring ≤5 PC at rated voltage.

    4. The testing process is simple, intuitive, and user-friendly.

    5. Effectively eliminates clutter interference from the power supply.

    6. Integrates automatic control technology, offering a high degree of automation and strong anti-interference capability.

    7. Equipped with a fast-acting electronic protection device, ensuring high reliability.


    Working principle:

    The control panel (box) with overcurrent automatic tripping and zero position interlocking device to prevent sudden pressurization of the power input is regulated by an autotransformer to input voltage into a non partial discharge filter isolation filter transformer, and then output from the non partial discharge filter isolation filter transformer

    To test the primary winding of the transformer, according to the principle of electromagnetic induction, the secondary (high voltage) winding can obtain an equal multiple of voltage amplitude - power frequency high voltage - based on the ratio of its turns to the primary winding.








    Bạn cũng có thể thích

    • Có bất kỳ câu hỏi nào!

      ĐỪNG ngần ngại LIÊN HỆ VỚI CHÚNG TÔI BẤT CỨ LÚC NÀO
      Liên hệ chúng tôi
    • Ghé thăm chúng tôi

      Tòa nhà 6, Khu công nghiệp Cơ khí Quang học Thung lũng Quang học, 84 Đường Gaoxin 5,
      Khu phát triển công nghệ mới Hồ Đông, thành phố Vũ Hán, tỉnh Hồ Bắc, Trung Quốc

    • Gửi email cho chúng tôi

      qiao@hvtest.cc

    • Gọi cho chúng tôi

      +86-15871365102