  • What are the technical requirements for a grounding resistance tester?

    The grounding resistance testerViệc sử dụng nguồn điện siêu cao áp có thể giúp nhiều công nhân điện lực thực hiện các thử nghiệm điện khác nhau một cách thuận tiện hơn.

    7

    The grounding resistance tester, combined with the new lightning protection grounding resistance detection standard, is carefully designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, and AC voltage. The test current reaches 20mA, and digital and microprocessing techniques are used to measure the grounding resistance using the 4-wire method, 3-wire method, and simple 2-wire method. Introducing FFT (Fast Fourier Transform) technology and AFC (Automatic Frequency Control) technology to automatically identify interference and select measurement frequency, minimizing the impact of interference and providing more accurate grounding resistance values.

    It has unique anti-interference ability and environmental adaptability, with good consistency in repeated testing, ensuring high precision, stability, and reliability for long-term measurement. Widely used for measuring grounding resistance, soil resistivity, grounding voltage, and AC voltage of electrical equipment in power, telecommunications, meteorology, oil fields, construction, lightning protection, and industrial applications.

    1. The grounding resistance tester should be placed at a distance of 1-3 meters from the testing point, and should be stable and easy to operate.

    2. Each terminal must have good contact and a secure connection.

    3. The two grounding electrode pins should be set at 20m and 40m on both sides of the tested ground body; If two pins are connected in a straight line, the grounding body to be tested should be basically on that line.

    4. Do not use other wires instead of the 5m, 20m, and 40m copper wires that come with the instrument.

    5. If the grounding resistance tester is centered, the minimum angle between the two pins and the tester must not be less than 120 ° and cannot be set in the same direction.

    6. The soil where the two pins are placed must be firm and cannot be placed on mud, backfill soil, tree roots, grass, etc.

    7. The grounding resistance can only be tested after 7 consecutive sunny days after rain.

    8. The tested grounding body should undergo rust removal treatment first to ensure reliable electrical connection.

    Bạn cũng có thể thích

    • Có bất kỳ câu hỏi nào!

      ĐỪNG ngần ngại LIÊN HỆ VỚI CHÚNG TÔI BẤT CỨ LÚC NÀO
      Liên hệ chúng tôi
    • Ghé thăm chúng tôi

      Tòa nhà 6, Khu công nghiệp Cơ khí Quang học Thung lũng Quang học, 84 Đường Gaoxin 5,
      Khu phát triển công nghệ mới Hồ Đông, thành phố Vũ Hán, tỉnh Hồ Bắc, Trung Quốc

    • Gửi email cho chúng tôi

      qiao@hvtest.cc

    • Gọi cho chúng tôi

      +86-15871365102